Application: In a solar power system of rated voltage Uo/U=0.6/1KV AC, 1000/1800V DC, Solar Cables (PV Cables) are used to connect between solar panels and inverters. –> Construction: Conductor: Soft tinned annealed copper according to VDE0295/IEC 60228, class 5. Insulation: Cross-linked polyethylene (XLPE) Jacket: EVA, Ethylene vinyl acetate, UV and ozone resistant. Jacket color: Black/Red Electrical Performance: Rated Voltage: Uo/U=0.6/1KV AC 1000/1800V DC For DC Installations Test Voltage:6500V/5min Thermal Performance: Operation temperature: -40ᵒC ~ +120ᵒC Ambient temperature: -40ᵒC ~ +90ᵒC Maximum Short-circuit temperature: 280ᵒC, +536ᵒF, 5s. Maximum conductor temperature of operation: 120ᵒC during 20000 hours. Bending Radius: Fixed setting: > 4 times of overall diameter i.e. 4 × ø. Moves on occasion: > 5 × ø Material Characteristics/standard: Fireproof performance: IEC 60332-1; IEC 60332-3-24 Smoke emission: IEC 61034; EN 61034-2 Low fire load: DIN 51900 Approval: PSQCA and PCSIR (Reports available on request) Applied standard: TUV 2 PfG 1169/08. 2007. Certifications: Tested from Third Party Labs Tested by Pakistan Council of Scientific Industrial Research (PCSIR) Approved by Pakistan Standards & Quality Control Authority (PSQCA) (Test Reports available on request)

Sale!

20,000 20,001

Add to Wishlist
Add to Wishlist
Share

    Reviews

    There are no reviews yet.

    Be the first to review “Application: In a solar power system of rated voltage Uo/U=0.6/1KV AC, 1000/1800V DC, Solar Cables (PV Cables) are used to connect between solar panels and inverters. –> Construction: Conductor: Soft tinned annealed copper according to VDE0295/IEC 60228, class 5. Insulation: Cross-linked polyethylene (XLPE) Jacket: EVA, Ethylene vinyl acetate, UV and ozone resistant. Jacket color: Black/Red Electrical Performance: Rated Voltage: Uo/U=0.6/1KV AC 1000/1800V DC For DC Installations Test Voltage:6500V/5min Thermal Performance: Operation temperature: -40ᵒC ~ +120ᵒC Ambient temperature: -40ᵒC ~ +90ᵒC Maximum Short-circuit temperature: 280ᵒC, +536ᵒF, 5s. Maximum conductor temperature of operation: 120ᵒC during 20000 hours. Bending Radius: Fixed setting: > 4 times of overall diameter i.e. 4 × ø. Moves on occasion: > 5 × ø Material Characteristics/standard: Fireproof performance: IEC 60332-1; IEC 60332-3-24 Smoke emission: IEC 61034; EN 61034-2 Low fire load: DIN 51900 Approval: PSQCA and PCSIR (Reports available on request) Applied standard: TUV 2 PfG 1169/08. 2007. Certifications: Tested from Third Party Labs Tested by Pakistan Council of Scientific Industrial Research (PCSIR) Approved by Pakistan Standards & Quality Control Authority (PSQCA) (Test Reports available on request)”

    Your email address will not be published. Required fields are marked *