Application: In a solar power system of rated voltage Uo/U=0.6/1KV AC, 1000/1800V DC, Solar Cables (PV Cables) are used to connect between solar panels and inverters. –> Construction: Conductor: Soft tinned annealed copper according to VDE0295/IEC 60228, class 5. Insulation: Cross-linked polyethylene (XLPE) Jacket: EVA, Ethylene vinyl acetate, UV and ozone resistant. Jacket color: Black/Red Electrical Performance: Rated Voltage: Uo/U=0.6/1KV AC 1000/1800V DC For DC Installations Test Voltage:6500V/5min Thermal Performance: Operation temperature: -40ᵒC ~ +120ᵒC Ambient temperature: -40ᵒC ~ +90ᵒC Maximum Short-circuit temperature: 280ᵒC, +536ᵒF, 5s. Maximum conductor temperature of operation: 120ᵒC during 20000 hours. Bending Radius: Fixed setting: > 4 times of overall diameter i.e. 4 × ø. Moves on occasion: > 5 × ø Material Characteristics/standard: Fireproof performance: IEC 60332-1; IEC 60332-3-24 Smoke emission: IEC 61034; EN 61034-2 Low fire load: DIN 51900 Approval: PSQCA and PCSIR (Reports available on request) Applied standard: TUV 2 PfG 1169/08. 2007. Certifications: Tested from Third Party Labs Tested by Pakistan Council of Scientific Industrial Research (PCSIR) Approved by Pakistan Standards & Quality Control Authority (PSQCA) (Test Reports available on request)
Sale!₨20,000 ₨20,001
Add to Wishlist
Add to Wishlist
Share
CategoriesAll Category, All Inverters, Electronics
Be the first to review “Application: In a solar power system of rated voltage Uo/U=0.6/1KV AC, 1000/1800V DC, Solar Cables (PV Cables) are used to connect between solar panels and inverters. –> Construction: Conductor: Soft tinned annealed copper according to VDE0295/IEC 60228, class 5. Insulation: Cross-linked polyethylene (XLPE) Jacket: EVA, Ethylene vinyl acetate, UV and ozone resistant. Jacket color: Black/Red Electrical Performance: Rated Voltage: Uo/U=0.6/1KV AC 1000/1800V DC For DC Installations Test Voltage:6500V/5min Thermal Performance: Operation temperature: -40ᵒC ~ +120ᵒC Ambient temperature: -40ᵒC ~ +90ᵒC Maximum Short-circuit temperature: 280ᵒC, +536ᵒF, 5s. Maximum conductor temperature of operation: 120ᵒC during 20000 hours. Bending Radius: Fixed setting: > 4 times of overall diameter i.e. 4 × ø. Moves on occasion: > 5 × ø Material Characteristics/standard: Fireproof performance: IEC 60332-1; IEC 60332-3-24 Smoke emission: IEC 61034; EN 61034-2 Low fire load: DIN 51900 Approval: PSQCA and PCSIR (Reports available on request) Applied standard: TUV 2 PfG 1169/08. 2007. Certifications: Tested from Third Party Labs Tested by Pakistan Council of Scientific Industrial Research (PCSIR) Approved by Pakistan Standards & Quality Control Authority (PSQCA) (Test Reports available on request)” Cancel reply
Reviews
There are no reviews yet.